Vyaire CareFusionViasys Vela Specifications
Dimensions
- Pneumatic Module
- Height: 10.5 in (26.7 cm)
- Width: 17 in (43.2 cm)
- Depth: 16 in (40.6 cm)
- User Interface Module
- Height: 13.75 in (35 cm)
- Wdth: 16.25 in 941.3 CM)
- Depth: 2.5 in (6.4cm)
- Viewable size: 12.1 in (diagonal
- Resolution: 800 x 600
- Weight:
- Ventilator (includes User Interface Module): 83 lb or 37,6 kg
- Ventilator and Compressor (internal): 90 lb or 40,8 kg
Environmental
- Storage Temperature: -20° to 60° C (-4° to 140° F)
- Operating Temperature: 5° to 40° C (41° to 104° F)
- Barometric pressure: 760 to 545 mmHg
Battery Power
- 1 Hour of Ventilator Use on Internal Battery (Standard) / 30 minutes Ventilator/Compressor
- 8 Hours of Ventilator Use on Internal (Standard) and External (Optional) Battery / 2 hours Ventilator and Compressor
Advanced Gas Blending system
- Air/Oxygen Blending: 21 to 100%
- Internal Heliox Blending System (option): All concentrations up to 80/20
Advanced Patient Monitoring
- Proximal Hot Wire Flow Sensor
- 24-hour trending of monitored respiratory parameters
Electrical / Pneumatic / Input / Output
- Gas Composition FiO2: 21 to 100%
- Pneumatic Input
- Air / Heliox: 20 to 80 psig (1.38 to 5.52 bar)
- Compressor (internal): 3 to 10 psig (0.21 to 0.69 bar)
- Oxygen: 20 to 80 psig (1.38 to 5.52 bar)
- Electrical
- A/C: 100, 120, 230, 240 VAC, 47 to 65 Hz
- D/C (Internal/External Battery); 20 to29 VDC
- Data I/O
- Analog Inputs (x2): 0 to 1, 5 VDC
- Video Output: SVGA
- Nurse Call : N.O. or N. C.
Setup
- Humidifier: Active and passive humidification
- Patient setu:p Alphanumeric patient ID
- Leak compensation: ON, OFF
Mode
- Mode type: A/C, SIMV, CPAP/PSV, NPPV (AC, SIMV, CPAP/PSV), PRVC
- Breath type: Volume, pressure, APRV/BiPhasic
- Apnea backup: Volume, pressure
Primary Settings
- Rate: 2 to 80 bpm
- Tidal volume: 50 mL to 2.0 L
- Inspiratory pressure: 1 to 100 cmH2O
- Peak flow: 10 to 140 L/min, (180 L/min spontaneous maximum)
- Inspiratory pause: OFF, 0.1 to 2.0 seconds
- Inspiratory time: 0.3 sec to 10.0 seconds
- Pressure support ventilation: (PSV) OFF, 1 to 60 cmH2O
- PEEP: 0 to 35 cmH2O
- Flow trigger: 1 to 20 L/min
- %O2: 21% to 100% FiO2
- Pressure: high /pressure low 0 to 60 cmH2O/ 0 to 40 cmH2O
- Time high / time: low 0.3 to 30 seconds / 0.3 to
- NPPV Pinsp: 1 to 40 cmH2O
- NPPV PSV: OFF, 1 to 40 cmH2O
Advanced Settings
- Bias flow: 10 to 20 L/min
- Volume limit: 50 mL to 2.5 L (available in PRVC/Vsync only)
- Assured volume: OFF, 50 mL to 2.0 L
- PC flow cycle: OFF to 70%
- PSV cycle: 5% to 70%
- PSV Tmax: 0.3 to 3.0 seconds
- Waveform: Decelerating, square
- T high sync: 0% to 50%
- T high PSV: ON, OFF
- T low sync: 0% to 50%
- Sigh: ON, OFF
- Vsync: ON, OFF
Manual Controls
- Manual breath One breath
- Expiratory hold Maximum 6 seconds
- Inspiratory hold Maximum 6 seconds
- Increase O2 100% O2 for 3 minutes
- MIP/NIF Maximum 30 seconds
- Nebulizer 1 to 60 minutes, synchronized
Alarms
- High pressure 5 to 120 cmH2O
- Low pressure OFF, 2 to 60 cmH2O
- Low minute volume OFF, 0.1 to 99.9 L
- High breath rate OFF, 3 to 150 bpm
- Apnea interval 10 to 60 seconds
- Alarm volume 65 to 85 db at one meter
- Low EtCO2 OFF, 1 to 150 mmHg (0.1 to 20 kPa)
- High EtCO2 OFF, 5 to 150 mmHg (0.7 to 20 kPa)