Intellivue MP50 Specifications
Dimensions
- Height: 12.99″ (33 cm)
- Width: 14.37″ (36.5 cm)
- Depth: 8.54″ (21.7 cm)
- Weight: < 14.8 lbs (8.6 kg)
Display
- Size (Diagonal): 12.1″ (30.73 cm)
- Resoltuion: 800 x 600
- Refresh rate: 60 Hz
- Useful Screen: 9.6″ x 7.2″ (24.6 x 18.4 cm)
- Pixel Size: 0.3075 x 0.3075 mm
Power
- Power Consumption: < 100W
- Line Voltage: 100 to 240 V ~
- Current: 1.6 to 0.7 A
- Frequency: 50/60 Hz
Performance
- Sweep Speed: 6.25, 12.5, 25, and 50 mm/s with ±5% accuracy
- Trends: 12 or 16 numerics @ 12 sec, 1 minute, 5 minute resolution. Multiple choices of number of numerics, resolution, and duration depending on application area
- Neonatal Event Review
- Information: trigger condition and time, event classification and associated detailed view of episode data
- Episode data: configurable, includes all current numerics, alarms and inops, and 4 minutes of high resolution trend
- Capacity (max): 25 or 50 events for 8 or 24 hours
- Buffered Memory
- Contents: Active settings, trends, snapshots, events, review alarms
- Hold Time: infinite if powered by AC; otherwise at least 48 hours (typical: >72 hours)
Environmental Conditions
- Temperature Range
- Operating: 0 to 35oC (32 to 95oF)
- Non-operating: -20 to 60oC (-4 to 140oF)
- Humidity Range:
- Operating: 20% to 85% Relative Humidity (RH) (non condensing)
- Non-operating: 5% to 85% Relative Humidity (RH)
- Altitude Range
- Operating: 0 m to 3000 m (10000 ft)
- Non-operating: 0 m to 12000 m (40000 ft)
- BatteryStorage: -20 to 50oC (-4 to 122oF)
Battery
- Type: High-power battery M4605A, 10.8 V 6000 mAh Lithium Ion
- Weight: 490 g per battery
- Status LEDs indicate charge status of batteries
- Safety: complies with UL1642 (UL recognised)
- Electromagnetic compatibility: complies with the requirements for FCC Type B computing Device, and EN 61000-4-2 and EN 61000-3
- Communication Standard: complies with the SMBus specification v1.1
- Battery Operating Time (New and fully loaded battery)
-
- With basic monitoring configuration: 5 hours (brightness set to optimum, MMS connected, NBP measurement every 15 minutes)
- With extended monitoring configuration: 4 hours (brightness set to optimum, MMS and MMS extension connected, NBP every 15
minutes, Recorder, Pressure, Temperature modules connected)
-
- Battery Charge Time:
- When monitor is switched off: 4 hours
- When monitor is in use: 5 to 12 hours, depending on monitor configuration