Philips IntelliVue MP5 PATIENT MONITOR

Philips IntelliVue MP5 PATIENT MONITOR

Philips IntelliVue MP5 Features

The Philips IntelliVue MP5 is a Compact patient monitor that can fit into a wide range of environments. The IntelliVue MP5 patient monitor has an 8.4 ” LCD touch screen display. The display screen offers flexible screen configuration. Showing up to four different waveform measurements simultaneously. The Philips IntelliVue MP5 can measure 12 lead ECG. The MP5 can be connected to an IntelliVue MP20 through an MP90 monitor and can be used like a Multi-Measurement Module (MMS). The system has dedicated configurations for anesthesia, critical and cardiac, and neonatal care.

  • Compact, rugged, lightweight monitor with built-in measurements
  • ECG monitoring using any combination of three to 10 electrodes.
  • 12-lead ECG monitoring with five electrodes using the EASI method or with 10 electrodes using the conventional method.
  • Multi-lead arrhythmia and ST segment analysis at the bedside on all available leads.
  • Respironics Mainstream or Sidestream CO2.
  • FAST SpO2 for accurate performance even with low perfusion.
  • Invasive Pressure and Temperature measurement.
  • Choice of either auscultatory or intra-arterial measurements as a measurement reference for Non-Invasive Blood Pressure.
Category: Tag:

Philips IntelliVue MP5 Specifications

Dimensions

  • Height: 9.76″ (24.8 cm)
  • Width: 10.2″ (25.9 cm)
  • Depth: 7.32″ (18.6 cm)
  • Weight: 8.8 lbs (4 kg)

Power

  • Power Consumption: < 40W average; < 65W Peak
  • Line Voltage: 100 to 240 V ~
  • Current: 1.3 to 0.7A
  • Frequency: 50/60 Hz

Display

  • Type: SVGA
  • Size: 8.4″ (21.3 cm)
  • Resolution: 800 x 600
  • Refresh Rate: 60 Hz

Battery

  • Type: Lithium-Ion
  • Capacity: 6000 mAh
  • Voltage: 10.8 V
  • Weight: 480g (Per battery)
  • Charge Time: 4 hours (When off); 5 hours or more when on
  • Operating Time: 4 Hours (Basic monitoring configuration); 3 hours (Extended monitoring configuration)

Operating Environmental Specifcaitons

  • Temperature: 32 to 104°F (0 to 40°C)
  • Humidity: 15 to 95% non condensing
  • Altitude: 10,000 ft (-500 to 3000 m)

Storage Environmental Specifcaitons

  • Temperature: -4 to 140°F (-20 to 60°C)
  • Humidity: 5 to 90% non condensing
  • Altitude: 15,000 ft (-500 to 4600 m)

Sweep Speeds

  • 6.25, 12.5, and 50 mm/s with +/- 5% accuracy

CO2

  • Range: 0 to 150 mmHg (0 to 20.0 kPa)
  • Accuracy: after 2 minutes warmup: For values between 0 and 40 mmHg:±2.0 mmHg (±0.29 kPa) For values from 41 to 70 mmHg: ±5% of reading For values from 71 to 100 mmHg: ±8% of reading The specifications are valid for standard gas mixtures, balance air, fully hydrated at 35°C, Pabs = 760 mmHg, flow rate = 2 l/min
  • Resolution: Numeric: 1.0 mmHg (0.1 kPa); Wave: 0.1 mmHg (0.01 kPa)
  • Stability: Short-term drift: ±0.8 mmHg over four hours; Long-term drift: Accuracy specification will be maintained over a 120 hour period

awRR

  • Range: 2 to 150 rpm
  • Accuracy: ±1 rpm

Warm-up Time

  • 2 minutes with CO2 transducer attached for full accuracy specification

Response Time

  • Less than 60 ms

Temperature

Temp

  • Range: –1 to 45 °C (30 to 113 °F)
  • Resolution: 0.1 °C (0.2 °F)
  • Accuracy: ±0.1 °C (±0.2 °F)

Average Time Constant

  • Less than 10 seconds

Alarms

  • Range: –1 to 45 °C (30 to 113 °F)
  • Adjustment: -1 to 35 °C (30 to 95 °F): 0.5 °C (1.0 °F) steps 35 to 45 °C (95 to 113 °F): 0.1 °C (0.2 °F) steps

Invasive Pressure Performance

Measurement Rnage

  • –40 to 360 mmHg

Pulse Rate

  • Range: 25 to 350 bpm
  • Accuracy: ±1% Full Range
  • Resolution: 1 bpm

Input Sensitivity

  • Sensitivity:5µV/V/mmHg (37.5µV/ V/kPa)
  • Adjustment range:±10%

Transducer

  • Load Impedance:200 to 2000 Ω (resistive)
  • Output Impedance:≤3000 Ω (resistive)

Frequency Response

  • dc to 12.5 Hz or 40 Hz

Zero Adjustment

  • Range: ±200 mmHg (±26 kPa)
  • Accuracy: ±1 mmHg (±0.1 kPa)
  • Drift: Less than 0.1mmHg/°C (0.013 kPa/ °C)

NBP Performance Specifications

Measurement Ranges

  • Systolic: Adult: 30 to 270 mmHg (4 to 36 kPa); Pedi: 30 to 180 mmHg (4 to 24 kPa); Neo: 30 to 130 mmHg (4 to 17 kPa)
  • Diastolic: Adult: 10 to 245 mmHg (1.5 to 32 kPa); Pedi: 10 to 150 mmHg (1.5 to 20 kPa); Neo: 10 to 100 mmHg (1.5 to 13 kPa)
  • Mean: Adult: 20 to 255 mmHg (2.5 to 34 kPa); Pedi: 20 to 160 mmHg (2.5 to 21 kPa); Neo: 20 to 120 mmHg (2.5 to 16 kPa)
  • Pulse Rage: Adult:40 to 300; Pedi: 40 to 300; Neo: 40 to 300

Accuracy

  • Max. Std. Deviation: 8 mmHg (1.1 kPa)
  • Max. Mean Error: ±5 mmHg (±0.7 kPa)

Pulse Rate Measurement Accuracy

  • 40 to 100 bpm: ± 5 bpm
  • 101 to 200 bpm: ± 5% of reading
  • 201 to 300 bpm: ± 10% of reading (average over NBP measurement cycle)

Heart Rate Range

  • 40 to 300 bpm

Measurement Time

  • Typical at HR > 60bpm
  • Auto/manual: 30 seconds (adult) 25 seconds (neonatal) Stat: 20 seconds
  • Maximum time: 180 seconds (adult/pediatric) 90 seconds (neonates)

Cuff Inflation Time

  • Typical for normal adult cuff: Less than 10 seconds
  • Typical for neonatal cuff: Less than 2 seconds

SpO2 Performance Specifications

Pulse

  • Range: 30 to 300 bpm
  • Accuracy: ±2% or 1 bpm, whichever is greater
  • Resolution: 1 bpm

Sensors

  • Wavelength range: 500 to 1000 nm
  • Emitted Light Energy: ≤ 15mW Information about the wavelength range can be especially useful to clinicians (for instance, when photodynamic therapy is performed)

Pulse Oximeter Calibration Range

  • 70 – 100%

ECG Arrhythmia and ST Performance

Cardiotach

  • Range: Adult/pedi: 15 to 300 bpm; Neo range: 15 to 350 bpm
  • Accuracy: ±1% of range
  • Resolution: 1 bpm
  • Sensitivity: ≥200 µVpeak

PVC Rate

  • Range: 0 to 300 bpm
  • Resolution: 1 bpm

ST Numeric

  • Range: -20 to +20 mm
  • Accuracy: ±0.5 mm or 15%, whichever is greater
  • Resolution: 0.1 mm

Sinus and SV Rhythm Ranges

  • Brady: Adult: 15 to 60 bpm; Pedi: 15 to 80 bpm; Neo: 15 to 90 bpm
  • Normal: Adult:60 to 100 bpm; Pedi: 80 to 160 bpm; Neo: 90 to 180 bpm
  • Tachy: Adult: > 100 bpm; Pedi: >160 bpm; Neo: >180 bpm

Bandwidth

  • Diagnostic Mode: Adult/neo/pedi: 0.05 to 150Hz
  • Extended Monitoring Mode: Neo/pedi: 0.5 to 150Hz
  • Monitoring Mode: Adult: 0.5 to 40Hz; Neo/pedi: 0.5 to 55Hz
  • Filter mode: Adult/neo/pedi: 0.5 to 20H

HR

  • Range: 15 to 300 bpm maximum delay: 10 seconds according to AAMI EC 13- 1992 standard