Siemens Maquet SERVO-s Specifications
Dimensions
- Height: 20.5” (52 cm)
- Width: 15” (38 cm)
- Depth: 11.8” (30 cm)
- Weight: 44 lbs (20 kg)
Parameter Settings
- Inspiratory tidal volume (ml): 100–2000
- Inspiratory minute volume (l/min): 0.5–60
- Apnea, time to alarm (s): 15–45
- PC/PS above PEEP (cmH2O): 0–(120 – PEEP)
- PC/PS above PEEP in NIV (cmH2O): 0–(62 – PEEP)
- PEEP (cmH2O): 0–50
- PEEP in NIV (cmH2O): 2–20
- CMV frequency (breaths/min): 4–100
- SIMV frequency (breaths/min): 1–60
- Breath cycle time, SIMV (s): 1–15
- PHigh (cmH20): (PEEP + 1)–50
- THigh (s): 0.2–30
- TPEEP (s): 0.1–10
- O2 concentration (%): 21–100
- I:E ratio: 1:10–4:1
- TInsp (s): 0.1–5
- TPause (% of breath cycle time): 0–30
- Flow trigger sensitivity level: 0–10
- Press. trigg sensitivity (cmH2O): -20–0
- Insp. rise time (% of breath cycle time): 0–20
- Insp. rise time (s): 0–0.4
- End inspiration (% of peak flow): 1–70
- End inspiration in NIV (% of peak flow): 10–70
- Oxygen Breaths: 100% for 1 minute
- Start Breath: Initiation of 1 breath (In SIMV mode initiation of 1 mandatory breath)
- Pause Hold: Insp. or exp (0–30 seconds)
Screen
- Type: TFT-LCD module
- Size: 12.1” (31 cm) diagonal
- Viewing area: 9.7” x 7.3” (24.6 x 18.5 cm)
Backup Parameter Settings
- Inspiratory Tidal Volume (ml): 100–2000
- PC Above PEEP (cmH2O): 5–(120 – PEEP)
- PC above PEEP in NIV (cmH2 O): 5–(62 – PEEP)
- CMV frequency (breaths/min): 4–100
- I:E ratio: 1:10–4:1
- TInsp (s): 0.1–5
Power
- Power Supply, Automatic Range Selection: 100–120 V AC ±10%, 50–60 Hz, or 220–240 V AC ±10%, 50–60 Hz
- External 12 V DC: 12.0 V–15.0 V DC, 10 A
- Battery Capacity: 2 rechargeable battery modules 12 V, 5 A, 3.5 Ah each
- Battery Backup Time: At least 1 h with 2 fully charged batteries
- Battery Recharge Time: Approximately 3h/battery
- Max Power Consumption: At 100–120 V: 2 A, 190 VA, 140 W; At 220–240 V: 1 A, 190 VA, 140 W
Controlled Invasive Ventilation
- PC (Pressure Control)
- VC (Volume Control)
- PRVC (Pressure Regulated Volume Control)
- Can be configured with alternative flow patterns: VC with flow adaptation; VC without flow adaptation; VC with decelerating flow
Supported Invasive Ventilation
- PS/CPAP (Pressure Support / Continuous Positive Airway Pressure)
Combined Invasive Ventilation
- SIMV (PC) + PS (Synchronized Intermittent Mandatory Ventilation)
- SIMV (VC) + PS
- SIMV (PRVC) + PS
- Bi-Vent/APRV (Airway Pressure Release Ventilation)
Non-Invasive Ventilation
- Leakage Compensation Level: Inspiratory, up to 200 l/min; Expiratory, up to 65 l/ min
- Leakage Overrange Detection: Automatic
- Disconnect Detection: Automatic
- Disconnect flow: Low; High; Disabled; Configurable 7.5 l/min; 40 l/min;
- Deactivates disconnect detection
- Connect Detection: Manual, or automatic via bias flow