Drager Savina

Drager Savina

Drager Savina Ventilator Features

The Drager Savina is a ventilator that can be used on a wide range of patients from pediatrics to adults. The System offers a variety of ventilation modes that allows for spontaneous breathing in all modes. With an internal turbine, there is no need for an air cylinder and external compressor anymore. The Savina was designed to be easy to read with a bright, high-resolution screen. The Savina offers both invasive and non-invasive ventilation. With the machine’s open breathing system with an integrated alarm system making it a flexible system that can easily be adapted for each patients ventilation situation.

  • Advanced, high-quality ICU ventilator that offers excellent ventilation performance combined with easy operation
  • Designed for both adult and pediatric ventilation, the Savina provides advanced therapy at any acuity level
  • Comprehensive safety concept
  • Increased flexibility
  • Supports the recovery process at every stage
  • Simple and effective user interface
Category: Tag:

Drager Savina Specifications

Dimensions (without Trolley)

  • Height: 156.1 in (383 mm)
  • Width: 15 in (180 mm)
  • Depth: 14.1 in (358 mm)
  • Weight (basic device): 53 lbs (24 kg)
  • Diagonal Screen Size: 6.1 in TFT color Screen

Measured value display

  • Airway pressure measurements: Peak pressure, plateau pressure, mean airway pressure, PEEP 0 -100 mbar (cmH2O)
  • Minute Volume (MV): Total MV, spontaneous MV 0 to 99 L/min, BTPS
  • Tidal Volume VT: Inspiratory VT, expiratory VT 0 to 3999 mL, BTPS
  • Breathing Frequency: Total and spontaneous breathing frequency, 0 -150 bpm
  • Inspiratory O2-concentration: 21 to100 Vol. %
  • Breathing gas temperature: 18 to 48 °C (sensor optional)
  • Curve displays: Airway pressure / time, flow / time
  • Ventilation Ratio (I:E):

Performance Data

  • Maximum flow for pressure assist/spontaneous breathing: 180 L/min
  • Value response to TO..90: ≤5 ms
  • Control principle: time-cycled, volume-constant, pressure-controlled
  • Safety valve opening pressure: 100 mbar (cmh2O)
  • Emergency value: automatically enables spontaneous breathing with filtered ambientair if air and O2 supply should fail.
  • Automatic gas switch-over function if O2 supply fails
  • Output for pneumatic medicament nebuliser : Synchronized with inspiration

Operating Data

  • Main Power connection: 100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC
  • Typical Power Consumption: 100W
  • Internal battery: Approx. 60 min ( optional extension up to 7h)

Gas Supply

  • Air: Turbine technology
  • O2 Gas Supply:

Ventilation Modes

  • IPPV (CMV), IPPVAssist (CMVAssist)
  • SIMV, SIMVASB (SIMV/PS)
  • CPAP, CPAPASB (CPAP/PS)
  • BIPAP1), (PCV+) (optional), BIPAP)ASB (PCV+/PS) (optional)

Enhancements

  • NIV – Non Invasive Ventilation with optimized alarm system and automatic leakage compensation (optional)
  • AutoFlow®
  • Automatic adaptation of the inspiratory flow in volume orientated ventilation modes (optional)
  • LPO – Low Pressure Oxygen. Independant oxygen supply, e.g. with an O2 concentrator (optional)
  • Graphic screen – Advanced ventilation monitoring (optional)
  • Nurse call – Connection for transmitting alarm signals to a central alarm system (optional)
Customer reviews
  • 0
    0 ratings
  • 5 Stars
    0%
    4 Stars
    0%
    3 Stars
    0%
    2 Stars
    0%
    1 Star
    0%
Reviews

There are no reviews yet.

Write a customer review

Be the first to review “Drager Savina”